A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 87 V Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   FLUKE 87 V (87V)   Description / Specification:    
FLUKE 87 V Handheld Digital Multimeter

The Fluke 87 V is a handheld digital multimeter with a broad range of functions including: AC/DC voltage and current, resistance, capacitance, frequency, duty cycle, temperature, conductance, diode test, duty cycle range, and measurements restriction in Ex-hazardous area. Maximum DC voltage measurement: 1000 V with an accuracy of +/-(0.05%+1), and a max resolution of 10 micro-volts. AC voltage maximum measurement: 1000 V, with an accuracy of +/-(0.7%+2) true rms. AC bandwidth: 20 kHz, and a maximum resolution of 10 micro-volts. DC current maximum reading: 10 A (20 A for 30 seconds max) with an accuracy of +/-(0.2%+2) and a max resolution of 0.01 micro-amperes. AC current maximum reading: 10 A (20 A for 30 seconds maximum) with an accuracy of +/-(1.0%+2) and a max resolution of 0.01 micro-amperes true-rms. Maximum resistance reading: 50 mega-ohms with an accuracy of +/-(0.2%+1) and max resolution of 0.01 ohms. Maximum capacitance reading: 9999 micro-farads with an accuracy of +/-(1%+2) and a max resolution of 0.001 nF. Maximum frequency reading: 200 kHz with an accuracy of +/-(0.005%+1) and a max resolution of 0.001 Hz. Duty cycle maximum reading: 99.90% with an accuracy of +/-(0.2% per kHz+0.1%) and a max resolution of 0.10%. Temperature range: -200.0 to 1090 degrees C. 80BK temperature probe range: -40.0 to 260 degrees C with an accuracy of 2.2 degrees or 2%, whichever is greater. Conductance maximum reading: 60.00 nS with an accuracy of +/-1.0%+10) and a max resolution of 0.001 nS. Diode test range: 3 V; resolution: 1 mV and an accuracy of +/-(2%+1). Duty cycle range accuracy: within +/-(0.2% per kHz + 0.1%). Measurements restriction in Ex-hazardous areas: voltage: 65 V; current: 5 A. ~400 hours of battety life. Analog display: 32 segments, updates 40/sec. Digital display: 6000 counts updates 4/sec. 19999 counts in high-resolution mode.



 

Standard Calibration $70.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 87 V. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your FLUKE 87 V CALIBRATION and/or FLUKE 87 V Handheld Digital Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: